How To Fix A Running Toilet: Fill Valve Or Flush Valve?

Fluidmaster 1/2″ BSP Telescopic Bottom Inlet Float Valve Brass Thread PRO45B

A running toilet can waste a surprising amount of water – and it is usually a simple fix. The trick is working out which part has failed.

Step 1: Find The Fault

  • Water trickling into the pan all the time – the flush valve is not sealing. Usually a worn washer/seal on the flush valve, or debris under it.
  • Water running out of the overflow – the fill valve is not shutting off, or the float is set too high.
  • Cistern slow to fill or not filling – fill valve fault or a partly closed isolating valve.

Step 2: Check The Easy Things First

  1. Lower the float on the fill valve so the water stops 25mm or so below the overflow.
  2. Clean any limescale or grit off the flush valve seal.
  3. Check the isolating valve on the supply pipe is fully open.

Step 3: Replacing A Part

If cleaning and adjusting do not cure it, replace the faulty part:

  1. Turn off the isolating valve (or the main stopcock) and flush to empty the cistern.
  2. Soak up the remaining water with a sponge.
  3. Note whether your fill valve is bottom entry or side entry – buy the matching type.
  4. Fit the new valve, hand-tighten the backnut plus a small turn with a spanner, reconnect and turn the water back on.
  5. Set the water level and check for drips under the cistern.

We stock Fluidmaster fill and flush valves, flush valve washers and isolating valves. Bring the old part in and we will match it.

Need a hand choosing? Pop into Hatch End Hardware at 366 Uxbridge Road, Pinner HA5 4HP, or call 020 8428 0581. Order online and collect in 1 hour.